AS 4678 Certified | Trade Accounts Welcome | 40+ Years Experience

AS 4678 Certified | Trade Accounts Welcome | 40+ Years Experience

Dy-Mark Spot Marking Paint 350g
Geo Matting | Geotextile Fabric for Retaining Wall Drainage
Ag Pipe 100mm x 20m | Slotted & Socked Drain Coil
Galvanised Steel Post Caps
Galvanised Steel Fence Bracket Kit
Builders Line Nylon Pink 100m

Material Estimator

Add your deal, information or promotional text

150 Series Steel Posts

150 Series Galvanised Steel Posts — Heavy Duty for Walls 1.0m–1.8m

The 150 Series is our heavy duty steel post range, engineered for concrete sleeper retaining walls between 1.0m and 1.8m in height, reactive clay soils, elevated surcharge loads, and sites where additional structural capacity is required. The larger section size provides significantly greater bending strength and stiffness compared to the 100 Series.

When to Use 150 Series Posts

  • Walls between 1.0m and 1.8m in height
  • Reactive clay soils that expand and contract seasonally (common across Brisbane, Melbourne, Adelaide, and Perth eastern suburbs)
  • Sites with elevated surcharge loads — driveways, vehicles, structures, or slopes
  • Where engineer certification is required or recommended
  • Coastal and high-moisture environments requiring additional corrosion resistance

150 Series Post Options

  • 150 UC 30 H-Beam — universal column section, maximum bending strength for demanding sites
  • 150 PFC C-Channel — parallel flange channel, heavy duty residential and light commercial
  • 45° Corner Joiner — for angled wall layouts at 150 Series specification
  • 90° Corner Joiner — for right-angle corners at 150 Series specification

For the most demanding structural applications, see our 200 Series Engineered Posts. For standard residential walls under 1.0m, see our 100 Series Posts.

Post selector

Find the right steel post for your wall

Set your wall details and site conditions. The selector recommends a post series, profile, embedment depth and footing size — and gives you a post count to take to a quote.

0.9 m
12 m
Post spacing (sleeper size)
Soil conditions
Load above the wall
Wall returns or corners?

Recommended post series

150 Series

H-beam (UC)

Standard soil, garden loading, wall under 1.0 m.

Line posts
End posts
Corner / joiner posts
Total posts
Post embedment
Footing diameter
Concrete per footing

Post series and embedment are indicative starting points based on published guidelines. Post profile, footing diameter, reinforcement and concrete specification must be confirmed by a qualified structural engineer for walls over 1 m, walls near boundaries, or walls carrying surcharge loads. AS 4678:2002 applies.

Search